2 boot block error beep codes – Intel SE7525GP2 User Manual
Page 137
Intel® Server Board SE7320SP2 & Intel Server Board SE7525GP2 TPS
Error Reporting and Handling
Revision 2.0
137
Error Code
Error Message
Response
8305
Primary Hot swap Controller failed to function
Pause
84F1
BIST failed for all available processors
Halt
84F2
Baseboard Management Controller failed to respond
Pause
84F3
Baseboard Management Controller in Update Mode
Pause
84F4
Sensor Data Record Empty
Pause
84FF
System Event Log Full
Warning
8500
Bad or missing memory in slot 3A
Pause
8501
Bad or missing memory in slot 2A
Pause
8502
Bad or missing memory in slot 1A
Pause
8504
Bad or missing memory in slot 3B
Pause
8505
Bad or missing memory in slot 2B
Pause
8506
Bad or missing memory in slot 1B
Pause
8600
Primary & Secondary BIOS ID's don't match.
Pause
8601
Override Jumper is set to force boot from lower bank of flash ROM.
Pause
8602
Watchdog Timer Expired (Secondary BIOS maybe bad!).
Pause
8603
Secondary BIOS CheckSum fail.
Pause
6.2.2
Boot Block Error Beep Codes
Table 59. Boot Block Error Beep Codes
Number of Beeps
Description
1
Insert diskette in floppy drive A:
2
‘AMIBOOT.ROM’ file not found in root directory of diskette in A:
3
Base Memory error
4
Flash Programming successful
5
Floppy read error
6
Keyboard controller BAT command failed
7
No Flash EPROM detected
8
Floppy controller failure
9
Boot Block BIOS checksum error
10
Flash Erase error
11
Flash Program error
12
‘AMIBOOT.ROM’ file size error
13
BIOS ROM image mismatch (file layout does not match image present in flash device)
1 long beep
Insert diskette with AMIBOOT.001 File for Multi-Disk Recovery