Intel® Server Board SE7320SP2 & Intel Server Board SE7525GP2 TPS

Platform Management

Revision 2.0

111

For more information on read-write through SMBus refer the System Management Bus (SMBus)
Specification 2.0.

5.2.5.5 LAN

Interface

The server board supports one DPC LAN interface via a UDP port 26Fh. The mBMC supports a
maximum of one simultaneous session across all authenticated channels. The server board
implements gratuitous ARP support according to the IPMI 1.5 Specification.

The IPMI Specification v1.5 defines how IPMI messages, encapsulated in RMCP packet format,
can be sent to and from the mBMC. This capability allows a remote console application to
access the mBMC and perform the following operations:

Chassis Control, e.g., get chassis status, reset chassis, power-up chassis, power-down
chassis

Get system sensor readings

Get and Set system boot options

Get Field Replaceable Unit (FRU) information

Get System Event Log (SEL) entries

Get Sensor Data Records (SDR)

Set Platform Event Filtering (PEF)

Set LAN configurations

In addition, the mBMC supports LAN alerting in the form of SNMP traps that conform to the IPMI
Platform Event Trap (PET) format.

Table 47: LAN Channel Capacity

LAN CHANNEL Capability

Options

Number of Sessions

1

Number of Users

1

User

Name NULL (anonymous)

User Password

Configurable

Privilege Levels

User, Operator, Administrator

Authentication Types

MD5

Number of LAN Alert Destinations

1

Address Resolution Protocol (ARP)

Gratuitous ARP