ICP DAS USA MSM-6226 User Manual
Page 256

9
10
11
12
13
……
set flow-control
Syntax:
set flow-control
Description:
To set up the flow control function of all ports.
Argument:
Possible value:
Example:
FEL2P-SW26 (port)# set flow-control 3-6 asymmetric
set speed-duplex
Syntax:
set speed-duplex
Description:
To set up the speed and duplex of all ports.
Argument:
auto : set auto-negotiation mode
10 : set speed to 10M
100 : set speed to 100M
1000 : set speed to 1000M
half : set to half duplex
full : set to full duplex
Possible value:
Example:
FEL2P-SW26(port)# set speed-duplex 10-15 10 full
FEL2P-SW26(port)# show status
asymmetric: set
5 TP Up Enable Enable 100M/Full ON OFF
6 TP Down Enable Enable ----/---- ---- ---- Engineer
7 TP Down Enable Enable ----/---- ---- ----
8 TP Down Enable Enable ----/---- ---- ---- sales