beautypg.com

ICP DAS USA MSM-6226 User Manual

Page 213

background image

Publication date: March., 2011

Revision A1

201

Syntax:
cable
Description:
To enable cable diagnostic function on switch
Argument:
: syntax: 1,5-7, available from 1 to 26
Possible value:
: 1 to 26.
Example:

FEL2P-SW26(diag)# cable 1-5
port 1: cable Ok (2 pairs, length +/- 10 meters)
pair A Ok, length 10 meters
pair B Ok, length 10 meters

diag

Syntax:
diag
Description:
Diag is used to test whether EEPROM, UART, DRAM and Flash is normal or not.
Argument:
None.
Possible value:
None.
Example:

FEL2P-SW26 (diag)# diag
EEPROM Test : OK
UART Test : OK
DRAM Test : OK
Flash Test : OK


Loopback


Syntax:
loopback
Description:
For Internal/External Loopback Test.
Argument:
None.
Possible value:
None.
Example:

FEL2P-SW26(diag)# loopback
Internal Loopback Test : OK


External Loopback Test : Port 2 3 4 6 8 9 10 11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 Fail