Set timer – ICP DAS USA MSM-6226 User Manual
Page 218

set restricted
Description:
To set the restricted mode for each port.
Argument:
Possible value:
Example:
FEL2P-SW26 (gvrp)# set restricted 1-10 enable
FEL2P-SW26 (gvrp)# show config
GVRP state: Enable
Port Join Time Leave Time LeaveAll Time Applicant Registrar Restricted
---- --------- ---------- ------------- --------------- --------- ----------
1 20 60 1000 Normal Normal Enable
2 20 60 1000 Normal Normal Enable
3 20 60 1000 Normal Normal Enable
4 20 60 1000 Normal Normal Enable
5 20 60 1000 Normal Normal Enable
6 20 60 1000 Normal Normal Enable
7 20 60 1000 Normal Normal Enable
8 20 60 1000 Normal Normal Enable
9 20 60 1000 Normal Normal Enable
10 20 60 1000 Normal Normal Enable
:
:
22 20 60 1000 Normal Normal Disable
23 20 60 1000 Normal Normal Disable
24 20 60 1000 Normal Normal Disable
25 20 60 1000 Normal Normal Disable
26 20 60 1000 Normal Normal
Disable
set timer
Syntax:
set timer
Description:
To set gvrp join time, leave time, and leaveall time for each port.
Argument:
Leave Time must equal double Join Time at least.
Possible value:
Example: