227
set reInitDelay
Syntax:
set reInitDelay
from 1 to 10 second(s)
Possible value:
from 1 to 10 second(s)
Example:
FEL2P-SW26(lldp)# set reInitDelay 5
FEL2P-SW26(lldp)#
set tlv
Syntax:
set tlv <0> <1> <2> <3> <4>
Description:
To set disable/enable lldp tlv
Argument:
Port Description: bit 0
System Name: bit 1
System Description: bit 2
System Capabilities: bit 3
Management Address: bit 4
port range syntax : 1,5-7, available from 1 to 10,
Management Address>: 0/1
Possible value:
syntax : 1,5-7, available from 1 to 10
Example:
FEL2P-SW26(lldp)# set tlv 1 1 1 1 1 1-10
FEL2P-SW26(lldp)#
set txDelay
Syntax:
set txDelay
Description:
To set lldp txdelay
Argument:
Possible value:
Example:
FEL2P-SW26(lldp)# set txDelay 500