5

Fault status detect

Null: no PD present

Overload: current support over 475mA @ DC 48V and

over 50 milliseconds

DR fail: PD discovery resistor is not in the limited range

Parametric

information

It will show current PD parameters, it include

Discover-resistor detected value, current, voltage, power

consumption, classification current and determined class

Port configuration

control

Port Disable / Enable.

PD detect control (enable/disable), Classification detect

control (enable/disable), DC disconnect detect control

Mode status

System detects status, it will show I –sample, V-sample

and R-detect.

NTP

Supports RFC 2030 Simple Network Time Protocol
(option)

SMTP

Supports RFC2821 Simple Mail Transfer protocol

(option)

System Log

System Log record up to 1000 entries

Power monitor

Support power supply monitoring function for AC power,

DC power, fan status

3 types of power supply can be installed with POE switch,

POW-DPW, POE-SPW, and POE-UPW.

Power testing

Support test function to testing power supply