beautypg.com

Milan Technology MIL-SM2401MAF User Manual

Page 117

background image

109

Port Enable: displays the POE port status. Y means the port is enabling. N means

the port is disabling and will not have any power providing but the port still can

transmit the data packet.

PwrLimitClass.: displays the power class limit status. N means the power class limit

is disabling. Y means the power class limit is enabling. The power limit class will

follow the value that set in the power limit max when is enabling.

PwrLimitManag.: displays the POE management that will follow or will not following

the priority rules.

Detect Legacy: The legacy detection is to identify the PD devices with unique

electrical signatures, that did not follow the IEEE 802.3af standard.

Priority: the port priority for power supply’s priority. 1 = C (critical), 2 = H (High), 3 = L

(Low).

PowerLimitMax: per port power output to PD’s power limit.

Fault Status: display the PD error status message. There are three error status and

explain as following.

Null: It means there is no PD connected or the connected PD device status is

normal.

POE management

Power Supply management