CAUTION
•
The frequency can be varied by RH (acceleration) and RM (deceleration)
between 0 and the maximum frequency (Pr. 1 setting).
•
When the acceleration or deceleration signal switches on, the set frequency
varies according to the slope set in Pr. 44 "second acceleration/deceleration time"
or Pr. 45 "second deceleration time". The output frequency acceleration and
deceleration times are as set in Pr. 7 "acceleration time" and Pr. 8 "deceleration
time", respectively. Therefore, the longer preset times are used to vary the actual
output frequency.
•
If the start signal (STF or STR) is off, turning on the acceleration (RH) or
deceleration (RM) signal varies the preset frequency.
CAUTION
When selecting this function, re-set the maximum frequency according to the
machine.
♦
♦
♦
♦
Related parameters
♦
♦
♦
♦
Maximum frequency setting
⇒
Pr. 1 "maximum frequency" (refer to page 59)
Output frequency acceleration/deceleration time
⇒
Pr. 7 "acceleration time",
Pr. 8 "deceleration time" (refer to page 62)
Time setting for acceleration/deceleration
⇒
Pr. 44 "second acceleration/deceleration time",
Pr. 45 "second deceleration time"
(refer to page 62)
2
.9 Terminal Function Selection Parameters
2
.9.1
Input terminal function selection
Use these parameters to select/change the input terminal functions.
Parameter
Name
Factory
Setting
Setting
Range
Remarks
60
RL terminal
function
selection
0
61
RM terminal
function
selection
1
62
RH terminal
function
selection
2
0 to 10,
14, 16
63
STR terminal
function
selection
- - -
0 to 10,
14, 16,
- - -
Setting is enabled when Pr. 30 = "1"