MITSUBISHI ELECTRIC FR-S520 User Manual
Page 64
55
2
Func-
tion
Com-
muni-
cation
Parame-
ter
Indica-
tion
Name
Setting Range
Minimum
Setting
Incre-
ments
Factory
Setting
Refer
To:
Cus-
tomer
Setting
n16
(992) *
PU main display
screen data
selection
0: Selectable
between
output
frequency
and output
current
100: (during stop):
Set
frequency,
output
current
(during
operation):
Output
frequency,
output
current
1
0
134
Communi
c
a
ti
on Par
a
m
e
te
rs
n17
(993)
PU
disconnection
detection/PU
setting lock
0: Without PU
disconnection
error,
1: Error at PU
disconnection,
10: Without PU
disconnection
error (PU
operation
disable)
1
0
135
For details of the program, refer to page 118 onwards.
REMARKS
1. The parameter numbers within parentheses are those for use of the parameter
unit (FR-PU04).
2. Set "9999" when setting a value "- - -" using the parameter unit (FR-PU04).
3. The decimal places of a value 100 or more (3 digits or more) cannot be
displayed.
4. The parameters marked * can be changed in setting during operation if "0"
(factory setting) is set in Pr. 77 "parameter write disable selection". (Note that
Pr. 53, Pr. 70 and Pr. 72 may be changed only during PU operation.)
Pammet
e
r Li
s
t