Appendix 1 parameter data code list – MITSUBISHI ELECTRIC FR-S520 User Manual
Page 186
177
APPENDIX 1 PARAMETER DATA CODE LIST
Data Code
Func-
tion
Parameter
Number
Name
Read Write
Computer
Link Data
Setting
Increments *
Link Parameter
Extension
Setting
(Data Code
7F/FF)
0
Torque boost
00
80
0.1%
0
1
Maximum frequency
01
81
0.01Hz
0
2
Minimum frequency
02
82
0.01Hz
0
3
Base frequency
03
83
0.01Hz
0
4
Multi-speed setting
(high speed)
04
84
0.01Hz
0
5
Multi-speed setting
(middle speed)
05
85
0.01Hz
0
6
Multi-speed setting
(low speed)
06
86
0.01Hz
0
7
Acceleration time
07
87
0.1s
0
8
Deceleration time
08
88
0.1s
0
9
Electronic thermal O/L
relay
09
89
0.01A
0
30
Extended function display
selection
1E
9E
1
0
Bas
ic
f
unct
ions
79
Operation mode selection
4F
None
1
0
The extended function parameters are made valid by setting "1" in Pr. 30 "extended
function display selection".
Data Code
Func-
tion
Parameter
Number
Name
Read Write
Computer
Link Data
Setting
Increments *
Link Parameter
Extension
Setting
(Data Code
7F/FF)
10
DC injection brake
operation frequency
0A
8A
0.01Hz
0
11
DC injection brake
operation time
0B
8B
0.1s
0
12
DC injection brake
voltage
0C
8C
0.1%
0
13
Starting frequency
0D
8D
0.01Hz
0
14
Load pattern selection
0E
8E
1
0
15
Jog frequency
0F
8F
0.01Hz
0
16
Jog acceleration/
deceleration time
10
90
0.1s
0
17
RUN key rotation
direction selection
11
91
1
0
19
Base frequency voltage
13
93
0.1V
0
20
Acceleration/deceleration
reference frequency
14
94
0.01Hz
0
21
Stall prevention function
selection
15
95
1
0
St
and
ar
d oper
at
io
n f
unc
ti
ons
22
Stall prevention operation
level
16
96
0.1%