MITSUBISHI ELECTRIC FR-S520 User Manual
Page 42
![background image](/manuals/123504/42/background.png)
33
1
Multi-Speed Setting
Terminal Input
Speed REX-
SD*
RH-
SD
RM-
SD
RL-
SD
Parameter
Set Frequency
Range
Remarks
Speed 1
(high
speed)
OFF ON OFF OFF
Pr. 4
0 to 120Hz
———————
Speed 2
(middle
speed)
OFF OFF ON OFF
Pr. 5
0 to 120Hz
———————
Speed 3
(low
speed)
OFF OFF OFF ON
Pr. 6
0 to 120Hz
———————
Speed 4 OFF OFF ON ON
Pr. 24
0 to 120Hz, - - - Pr. 6 setting when Pr. 24="- - -"
Speed 5 OFF ON OFF ON
Pr. 25
0 to 120Hz, - - - Pr. 6 setting when Pr. 25="- - -"
Speed 6 OFF ON ON OFF
Pr. 26
0 to 120Hz, - - - Pr. 5 setting when Pr. 26="- - -"
Speed 7 OFF ON ON ON
Pr. 27
0 to 120Hz, - - - Pr. 6 setting when Pr. 27="- - -"
Speed 8 ON OFF OFF OFF
Pr. 80
0 to 120Hz, - - - 0Hz when Pr. 80="- - -"
Speed 9 ON OFF OFF ON
Pr. 81
0 to 120Hz, - - - Pr. 6 setting when Pr. 81="- - -"
Speed 10 ON OFF ON OFF
Pr. 82
0 to 120Hz, - - - Pr. 5 setting when Pr. 82="- - -"
Speed 11 ON OFF ON ON
Pr. 83
0 to 120Hz, - - - Pr. 6 setting when Pr. 83="- - -"
Speed 12 ON ON OFF OFF
Pr. 84
0 to 120Hz, - - - Pr. 4 setting when Pr. 84="- - -"
Speed 13 ON ON OFF ON
Pr. 85
0 to 120Hz, - - - Pr. 6 setting when Pr. 85="- - -"
Speed 14 ON ON ON OFF
Pr. 86
0 to 120Hz, - - - Pr. 5 setting when Pr. 86="- - -"
Speed 15 ON ON ON ON
Pr. 87
0 to 120Hz, - - - Pr. 6 setting when Pr. 87="- - -"
External
setting
OFF OFF OFF OFF
Frequency
setting
potentiometer
0 to max. setting
———————
*When using the REX signal, a reverse rotation start cannot be made by the
external command.
10
2
5
Power supply
Forward rotation
Multi-speed
selection
Frequency
setting
potentiometer
Inverter
R 1 > S T U V W STF REX RH RM RL SD IM Motor *2 *1 Multi-Speed Operation Connection Example REMARKS *1: When the frequency setting potentiometer is connected, the input signal of the frequency setting potentiometer is ignored if the multi-speed select signal is *2: For a reverse rotation start, set Pr. 63 to "- - -" (factory setting).
switched on. (This also applies to the 4 to 20mA input signal.)