beautypg.com

3) single-phase 200v power supply – MITSUBISHI ELECTRIC FR-S520 User Manual

Page 172

background image

163

(3) Single-phase 200V power supply

Japanese version

FR-S520S-0.1K to 1.5K (-R)

EC version

FR-S520S-0.2K to 1.5K-EC (R)

Type FR-S520S- K(-R)

0.1

0.2

0.4

0.75

1.5

kW

0.1

0.2

0.4

0.75

1.5

Applicable motor capacity

(*1)

HP

1/8

1/4

1/2

1

2

Rated capacity (kVA) (*2)

0.3

0.5

1.0

1.6

2.8

Rated current (A)

0.8

1.4

2.5

4.1

7.0

Overload capacity (*3)

150% 60s 200% 0.5s (Inverse time characteristics)

Out

put

Voltage (*4)

Three phase, 200V to 240V 50Hz/60Hz

Rated input AC (DC) voltage,

frequency

Single-phase, 200V to 240V 50Hz/60Hz

Permissible AC (DC) voltage

fluctuation

170 to 264V 50Hz/60Hz

Permissible frequency

fluctuation

±

5%

Power

s

uppl

y

Power supply system

capacity (kVA) (*5)

0.5

0.9

1.5

2.5

4.4

Protective structure (JEM1030)

Enclosed type (IP20)

Cooling system

Self-cooling

Forced air

cooling

Approximate weight (kg (lbs))

0.5

(1.1)

0.6

(1.32)

0.8

(1.76)

1.0

(2.2)

1.5

(3.3)

*1. The applicable motor capacity indicated is the maximum capacity applicable

when a Mitsubishi 4-pole standard motor is used.

*2. The rated output capacity indicated assumes that the output voltage is 230V.
*3. The % value of the overload capacity indicates the ratio of the overload current

to the inverter's rated output current.
For repeated duty, allow time for the inverter to return to or below the
temperatures under 100% load.

*4. The maximum output voltage cannot exceed the power supply voltage. The

maximum output voltage may be set as desired below the power supply
voltage. However, the PWM pulse voltage value of the inverter output side
voltage remains unchanged at about

2

that of the power supply.

*5. The power supply capacity changes with the values of the power supply side

inverter impedances (including those of the input reactor and cables).

This manual is related to the following products: