beautypg.com

9 load pattern selection [p14, 9 load pattern selection – MITSUBISHI ELECTRIC FR-S520 User Manual

Page 75

background image

66

2

.3.9

Load pattern selection

You can select the optimum output characteristic (V/F characteristic) for the

application and load characteristics.

Forward

rotation

Reverse

rotation

For constant-torque
loads
(e.g. conveyor, cart)

100%

Ou

tp

ut

vo

lt

a

g

e

Base frequency

Output frequency (Hz)

Pr.14=0

For variable-torque
loads
(Fan, pump)

100%

Base frequency

Output frequency (Hz)

Pr.14=1

100%

Base frequency

Output frequency (Hz)

Forward

rotation

Pr.14=2

Pr.0
Pr.46

Pr.14=3

100%

Base frequency

Output frequency (Hz)

Pr.0
Pr.46

For lift

Ou

tp

ut

vo

lt

a

g

e

Ou

tp

ut

vo

lt

a

g

e

Ou

tp

ut

vo

lt

a

g

e

For lift

Reverse

rotation

Boost for forward rotation
...Pr. 0 (Pr.46) setting

Boost for forward rotation
...0%

Boost for reverse rotation
...0%

Boost for reverse rotation
...Pr. 0 (Pr.46) setting

Parameter

Name

Factory

Setting

Setting

Range

Remarks

14

Load pattern

selection

0

0, 1, 2,

3

0: For constant-torque loads

1: For variable-torque loads

2: For vertical lift loads

3: For vertical lift loads

Setting is

enabled

when Pr. 30

= "1".

CAUTION

1. When automatic torque boost control is selected, this parameter setting is

ignored.

2. Pr. 46 "second torque boost" is made valid when the RT signal turns on.

The RT signal acts as the second function selection signal and makes the other
second functions valid.

Related parameters

Automatic torque boost

Pr. 98 "automatic torque boost selection (motor capacity)" (refer to

page 109)

Boost setting

Pr. 0 "torque boost", Pr. 46 "second torque boost" (refer to page 58)

Assignment of RT signal to terminal when second torque boost is used

Pr. 60 to Pr. 63 (input terminal function selection) (refer to page 88)

This manual is related to the following products: