MITSUBISHI ELECTRIC FR-S520 User Manual
Page 58

49
2
Func-
tion
Pa-
rame-
ter
Indica-
tion
Name
Setting Range
Minimum
Setting
Increments
Factory
Setting
version>
Refer
To:
Cus-
tomer
Setting
48
Output current
detection level
0 to 200%
1%
150%
80
49
Output current
detection
signal delay
time
0 to 10s
0.1s
0s
80
50
Zero current
detection level
0 to 200%
1%
5%
81
C
u
rr
en
t de
te
ction
51
Zero current
detection time
0.05 to 1s
0.01s
0.5s
81
52 *
Control panel
display data
selection
0: Output frequency,
1: Output current,
100: Set frequency
during stop/output
frequency during
operation
1
0
82
53 *
Frequency
setting
operation
selection
0: Setting dial
frequency setting
mode
1: Setting dial
potentiometer mode
1
0
83
54 *
FM (AM)
terminal
function
selection
0: Output frequency
monitor
1: Output current
monitor
1
0
82
55 *
Frequency
monitoring
reference
0 to 120Hz
0.1Hz
60Hz
<50Hz>
84
Di
s
p
la
y f
u
nc
ti
ons
56 *
Current
monitoring
reference
0 to 50A
0.1A
Rated
output
current
84
57
Restart
coasting time
0 to 5s, - - -
0.1s
- - -
84
A
u
to
ma
tic r
e
sta
rt
func
ti
o
n
s
58
Restart
cushion time
0 to 60s
0.1s
1s
84
Ad
di
ti
o
nal
f
u
nc
ti
on
59
Remote
setting
function
selection
0: Without remote
setting function
1: With remote setting
function
With frequency
setting storage
function
2: With remote setting
function
Without frequency
setting storage
function
1
0
86
Pammet
e
r Li
s
t