3 monitoring reference [p55] [p56, 7 restart operation parameters, 1 restart setting [p57] [p58 – MITSUBISHI ELECTRIC FR-S520 User Manual

Page 93: 3 monitoring reference, 1 restart setting, Setting

background image

84

2

.6.3

Monitoring reference

Set the frequency or
current which is
referenced when the
output frequency or
output current is selected
for the FM (AM) terminal.

The Japanese

version has the FM
terminal feature, and
the NA and EC
versions have the AM
terminal feature.

1440 pulses/s (terminal FM)

Output
frequency

Pr.55

1440 pulses/s (terminal FM)

Output
frequency

Pr.56

Ou

tp

ut

o

r

di

s

p

la

y

Ou

tp

ut

o

r

di

s

p

la

y

(5VDC (terminal AM))

(5VDC (terminal AM))

Parameter

Name

Factory

Setting

Setting

Range

Remarks

55

Frequency monitoring
reference

60Hz

<50Hz>

0 to 120Hz

56

Current monitoring
reference

Rated output

current

0 to 50A

Setting is enabled
when Pr. 30 = "1"

Refer to the above diagrams and set the frequency monitoring reference value in
Pr. 55 and the current monitoring reference value in Pr. 56.
Pr. 55 is set when Pr. 54 "FM (AM) terminal function selection" = "0" and Pr. 56 is set
when Pr. 54 = "1".
Set the Pr. 55 and Pr. 56 values so that the output pulse train output of terminal FM is
1440 pulses/s (the output voltage of terminal AM is 5V).

CAUTION

The maximum pulse train output of terminal FM is 2400pulses/s. If Pr. 55 is not

adjusted, the output of terminal FM will be filled to capacity. Therefore, adjust Pr. 55.

The maximum output voltage of terminal AM is 5VDC.

2

.7 Restart Operation Parameters

2

.7.1

Restart setting

At power restoration after an instantaneous power failure, you can restart the
inverter without stopping the motor (with the motor coasting).

Parameter

Name

Factory

Setting

Setting

Range

Remarks

57

Restart
coasting time

- - -

0 to 5s,

- - -

58

Restart cushion
time

1s

0 to 60s

Setting is enabled when Pr. 30 = "1"