beautypg.com

MITSUBISHI ELECTRIC FR-S520 User Manual

Page 166

background image

157

3

.3.8 Measurement of main circuit voltages, currents and powers

Measurement of voltages and currents

Since the voltages and currents on the inverter power supply and output sides
include harmonics, accurate measurement depends on the instruments used and
circuits measured.
When instruments for commercial frequency are used for measurement, measure
the following circuits using the instruments given on the next page.

:Moving-iron type

:Electrodynamometer type

:Moving-coil type

:Rectifier type

+

-

Ar

As

At

Vr

Vs

Vt

W11

W12

W13

Au

Av

Aw

Vu

Vv

Vw

W21

W22

V

R

S

T

P

U

V

W

N

Instrument
types

Three-phase 200V
power input
Three-phase 400V
power input

Input
voltage

Input
current

Output
voltage

Output
current

Inverter

3-phase

power supply

To motor

Single-phase 200V

power input

Single-phase 100V

power input

The FR-S520S-0.1K to 1.5K
and FR-S510W-0.1K to
0.75K do not have As, At,
Vt, Vs, W12 and W13.

Typical Measuring Points and Instruments

CAUTION

Use FFT (Fast Fourier Transforms) to measure the output voltage accurately.

It cannot be measured accurately with a meter or general instrument.