DESIGN

INFORMATION

Design Information

42" Built-In Refrigerator

Flush or
Semi-Flush
Enclosure
Installations

Side Panel Requirements:
• Side panels are not required whenever the

refrigerator is installed into an enclosure or between
pantry and oven cabinets.

• Side panels are required whenever the sides of the

refrigerator are exposed.

• Side panel sizes vary depending on the type of

installation being made.

To accomplish an attractive installation, you must:
1. Determine the need for side panels.
2. Determine side panel thickness.
3. Order matching side panels from the cabinet

manufacturer. Be sure to provide the exact
dimensions.

True Flush Installation

In a flush installation,

the refrigerator doors

will align evenly with the

front face of adjacent cabinet

doors. The refrigerator blends

into the surrounding cabinetry.

Semi-Flush Installation

These refrigerators

can also be installed

semi-flush into an enclosure

using the minimum cutout

width. The case trim creates a

frame around the opening.

Monogram built-in refrigerators can be installed flush
with typical 24-3/4" deep cabinetry.

When installed semi-flush, the case trim will conceal
slight gaps around the enclosure. The refrigerator will
project forward approximately 3/4" beyond the front
face of surrounding cabinetry.

In any installation situation, a wide range of appear-
ance options can be accomplished through the use of
one or more trim kits. See trim kit descriptions and
appearance options on page 5.

Enclosure
Cutout and
Product
Dimensions

• To achieve a flush fit the finished cutout width must

be at least 42" wide.

• A semi-flush installation requires 41-1/2" min. finished

cutout width.

• The electrical and water locations must be located as

shown for either type of installation.

*42" Min. for a flush installation
41-1/2" Min. for a semi-flush installation
Note: Additional cutout width may be required when
side panels are used. Add side panel thickness to the
finished cutout to calculate rough-in width. See
installation examples on the following page.

0"

3/4"

Advance Planning

42"

83" Min
84-1/2" Max

24-3/4"

*Finished Width

7"

Wall View

Electrical

Area

84 1/2" max

83-1/4" min

Finished
Opening

74" From Floor

to Bottom

of Electrical

5"

18 3/8"

5"

3 1/2"

5"

3 1/2"

Water Supply

24 3/4" Total

Depth