Selecting the calibrate ribbon tab, Selecting the calibrate ribbon tab -22 – FARGO electronic HDPii User Manual
Page 303

RESTRICTED USE ONLY
Fargo Electronics, Inc.
HDPii High Definition Card Printer/Encoder User Guide (Rev. 1.1)
9-22
Selecting the Calibrate Ribbon tab
The two buttons for the Calibrate Ribbon tab are described below.
• Calibrate button: Sends the Calibrate Ribbon Command to Printer. Follow the
instructions below to set up the Printer.
• Help button: Launches help specific to this tab.
Step Procedure
1
Select the Calibrate Ribbon tab.
a. Ensure that the Ribbon Cartridge is removed.
b. Ensure the Printer’s Cover is closed.
c. Click on the Calibrate button. (Note: The Printer’s LCD will display
CALIBRATE PASSED.)
d. Click on the OK button on the LCD display to complete the procedure.