beautypg.com

Adjusting the transfer dwell time and temperature – FARGO electronic HDPii User Manual

Page 242

background image

RESTRICTED USE ONLY

Fargo Electronics, Inc.

HDPii High Definition Card Printer/Encoder User Guide (Rev. 1.1)

7-55

Adjusting the Transfer Dwell Time and Temperature

Use the Image Transfer option to control of the Transfer Dwell Time and Transfer
Temperature
.

• These settings control the speed and temperature at which printed images are

transferred from the Film to the card. These settings may vary depending on the card
type.

• The Printer Driver automatically optimizes these settings according to the selection made

in the Card Type option.

• Changes made to the Dwell Time and temperature settings are saved for the selected

Card Type option (upon exiting the Printer Driver setup in the Printer’s Control Panel).

Step Procedure

1

Transfer Dwell Time Sets dwell time for InTM transfer in seconds per inch
Lower limit = 1.0 seconds per inch, Upper limit = 3.0 seconds per inch

UltraCard III - Composite: Default = 2.0 seconds per inch
UltraCard - PVC: Default = 2.0 seconds per inch
Custom: Default = 2.0 seconds per inch