5 simple troubleshooting – Furuno GP-3500F User Manual
Page 222
12. MAINTENANCE & TROUBLESHOOTING
12-4
12.5 Simple
Troubleshooting
This section provides simple troubleshooting procedures which the user can
follow to restore normal operation. If you cannot restore normal operation do not
attempt to check inside the unit. Any trouble should be referred to a qualified
technician.
General troubleshooting
If… Then…
●
check for blown fuse.
●
check that the power connector is firmly fastened.
●
check for damaged power cable.
you cannot turn on the power
●
check battery for proper voltage output.
no picture appears
●
press the [BRILL] key for several times.
there is no response when a key
is pressed
●
turn off and on the power.
Plotter troubleshooting
If… Then…
●
check that antenna connector is firmly
fastened.
position is not fixed within 90 seconds
●
check number of satellites received, on the
GPS STATUS display.
●
check that the correct geodetic chart system is
selected on the NAVIGATOR SETUP menu.
position is wrong
●
enter position offset, on the NAVIGATOR
SETUP menu.
●
check that “1. ON” is selected at DISP
TRACKS (HOLD) in the MARKS/SHIP’S
TRACKS SETUP menu.
the track is not plotted
●
check that “1. ON” is selected at SHIP’S
TRACKS DISP in the MARKS/SHIP’S
TRACKS SETUP menu.
Loran C (or Decca) TDs are wrong
●
enter TD offset on the PLOTTER SETUP
menu.
Bearing is wrong
●
check the MAGNETIC VARIATION in the
DISPLAY SETUP menu.
The ship’s speed indication is not zero after
the ship is stopped
●
try to decrease speed/course smoothing.