Fortinet FortiLog-400 User Manual
Page 53
Managing the FortiLog unit
Alert Email
FortiLog Administration Guide
05-16000-0082-20050115
53
Figure 25: Device alert settings
Alert Name
Enter a name to identify the alert settings.
Devices to Monitor Select the device logs the FortiLog unit monitors. Expand the device
groups to select individual devices.
Level
Set the level of message that the FortiLog unit monitors for. The FortiLog
unit sends alert email for all messages at and above the logging severity
level you select.
Level wait interval Set the number of events and the time frame. The FortiLog unit will send
an alert email when the conditions are satisfied. For example, if you set
the alert to three events in one hour, after three events within that time the
FortiLog unit sends an alert email.
Attack Type
Set the type of attack that the FortiLog device should look for. Select any
attack or specific attack identifiers.
Attack Type Entry
and listing
When you select “Just these” for the attack type, enter the names of the
virus and select Insert.
Level of wait
interval
Set the number of attacks and the time frame. The FortiLog unit will not
send an alert email until the conditions are met.