5. Measuring
3)
Number of Pre-flash
For red-eye prevention and auto-flash light adjustment, some devices can pre-flash
before main flash burst.
With the normal setting, the light meter will measure the pre-flash bursts and not the main
flash burst. To take a successful reading, activate the pre-flash feature in the Tool Box.
Operation
1.
Touch the [Tool Box] Icon (
) on the Measuring Screen.
The Tool Box Screen is displayed.
2.
Touch the [Next Page] Icon (
) of the Tool Box to display the
Tool Box showing "Number of Pre-flash".
This button is enabled if Flash Mode is selected.
If it is grayed out, check the Measuring Mode.
3.
Touch the [Number of Pre-flash] Button of the Tool Box.
The Number of Pre-flash Screen is displayed.
If you do not change this number, touch the [Close] Button.