6. Functions
6.
Functions
6-1
Memory Function
This meter can save measured values in the memory. This function is available in the
following Measuring Modes.
Ambient Mode
●
T Priority Mode
●
F Priority Mode
●
TF Priority Mode
●
HD Cine Mode
●
Cine Mode
Flash Mode
●
Cord in (PC) Mode
●
Cordless Mode
●
Radio Triggering Mode
HSS Flash Mode
●
HSS Flash Cordless Mode
You can save (in the memory) and recall up to nine measured values regardless of
whether the incident light system or reflected light system is selected.
NOTE
●
When you have used the incident light system to save measured values in the memory
and then changed the system to the reflected light system, the measured values that
are saved in the memory using the incident light system are maintained. Then, you can
newly display measured values saved in the memory using the reflected light system.
●
In Ambient Mode, the measured values saved in the memory are maintained even if the
mode is switched.
In Flash Mode, the measured values saved in the memory are not maintained if the
mode is switched.