Sekonic Speedmaster L-858D-U Light Meter User Manual
Page 168

154
6. Functions
8.
Edit the camera sensitivity characteristics.
Set Camera Sensitivity
Characteristic Screen
Compensation
Value Cursor
Compensation Value
(Synchronized with the cursor)
Clipping Point (-)
Dynamic Range (-)
Dynamic Range (+)
Clipping Point (+)
[Cancel] Button
[Default] Button
[OK] Button
1
Compensation value cursor
The compensation value can be set between -5 EV and +5 EV in 0.1 EV step
increments.
While touching the compensation value cursor, slide the cursor to set the
compensation value.
You can also touch the Minus or Plus Icon (
or
) to change the value in
0.1 EV step increments each time it is clicked.
2
Dynamic range and clipping point
The dynamic range and clipping point can be set between -10 EV and +10 EV in 0.1 EV
step increments. However, the clipping point cannot be set over the dynamic range.
Dynamic range (-) ≤ Clipping point (-) ≤ Clipping point (+) ≤ Dynamic range (+)
While touching each cursor, slide the cursor to set the dynamic range (-), clipping
point (-), clipping point (+), and dynamic range (+).
To edit the dynamic range, touch the Minus or Plus Icon (
or
).
To edit the clipping point, touch the Minus or Plus Icon (
or
).
3
Default
If you touch [Default] Button, the profile of the selected ISO sensitivity is reset to the
default. To reset all the profiles to their defaults, use "Data Transfer Software", which
is a convenient tool.
9.
Touch [OK] Button.
The display returns to the ISO sensitivity selection on Edit Exposure Profile Data
Screen.
Touch [Cancel] Button to return to the ISO sensitivity selection on Edit Exposure Profile
Data Screen without changing any data.