Filter names and compensation values, P199), 6 filter names and compensation values – Sekonic Speedmaster L-858D-U Light Meter User Manual
Page 213
199
9. Various Setting Values
9-6
Filter Names and Compensation Values
The following table shows the L-858D's default filter names and compensation values that
are displayed when a filter name is selected. In addition to these values, you can register
up to 30 filter names.
No.
Filter Name
Compensation value (EV value)
1
ND0.3
-1.0
2
ND0.6
-2.0
3
ND0.9
-3.0
4
CTO Double
-2.1
5
CTO Full
-1.1
6
CTO Three-Quarter
-0.8
7
CTO Half
-0.5
8
CTO Quarter
-0.3
9
CTO Eighth
-0.1
10
No.85
-0.8
11
CTB Double
-3.3
12
CTB Full
-1.5
13
CTB Three-Quarter
-1.3
14
CTB Half
-0.9
15
CTB Quarter
-0.4
16
CTB Eighth
-0.3
17
Minusgreen Full
-0.9
18
Minusgreen Half
-0.5
19
Minusgreen Quarter
-0.3
20
Minusgreen Eighth
-0.2
21
Plusgreen Full
-0.4
22
Plusgreen Half
-0.2
23
Plusgreen Quarter
-0.1
24
Plusgreen Eighth
-0.2