96
5. Measuring
3.
Set the light receiving method.
Incident light system Switch to the extended lumisphere (
)/retracted lumisphere
(
). (
4.
Set the ISO sensitivity value on the [ISO] Icon.
5.
Set the shutter speed on the [T] Icon.
Measuring Screen
Setting Value
NOTICE
● Make sure that the settings are within the specifications
of the camera and flash system.
● If the measured flash duration time is longer than the
input shutter speed, an appropriate F-stop cannot be
measured. The yellow "Under" indication appears.
In this case, slower the shutter speed than the flash
duration time and measure again.
6.
Set the Flash Duration Analysis t value.
7.
Press the Measuring Button
6
.
The meter will enter the Measuring Standby Mode, and the Measuring Mode Icon
(
) will blink for 90 seconds. The LCD screen dims and stands by.
Measuring