7. Hardware Setting
obtained using another light meter>
1.
Touch the [User Calibration] Button.
The User Calibration Screen is displayed.
User Calibration Screen
[Close] Button
Calibration
Value
Adjustment Button
(+)
Adjustment Button
(-)
2.
Press the Measuring Button
6
.
The User Calibration Screen allows you to make measurements, thus you can equalize
measured values obtained using another light meter under the same light source.
3.
Adjust the calibration value.
Touch the Adjustment Button (
) or (
) to adjust the calibration value in
increments of +/-0.1 EV.
4.
Touch [Close] Button.
Finish the setting, and return to the Hardware Setting Screen.
NOTICE
●
User calibration carried out in Hardware Setting is not displayed on the
status bar.
● Calibration of the measured value must be performed based on a sufficient
number of test shooting results.
●
Note that the individual compensation is possible in the incident light
system and reflected light system while uniform compensation is applied
in Ambient Mode and Flash Mode.