RETI NC

Operation:

C=0: IP

← @SP--

IPS

← 11b

C=1: IP

← IP +1

Encoding:

15

0

1110

1100

1000

1101

Example(s):

RETI NC

; C=1, return from interrupt (RETI) does not occur

RETI Z

Operation:

Z=1: IP

← @SP--

IPS

← 11b

Z=0: IP

← IP + 1

Encoding:

15

0

1001

1100

1000

1101

Example(s):

RETI Z

; Z=0, return from interrupt (RETI) does not occur

RETI NZ

Operation:

Z=0: IP

← @SP--

IPS

← 11b

Z=1: IP

← IP + 1

Encoding:

15

0

1101

1100

1000

1101

Example(s):

RETI NZ

; Z=0, return from interrupt (RETI) is performed

RETI S

Operation:

S=1: IP

← @SP--

IPS

← 11b

S=0: IP

← IP + 1

Encoding:

15

0

1100

1100

1000

1101

Example(s):

RETI S

; S=0, return from interrupt (RETI) does not occur