40 / MATERIAL SETUP
PRESET METHOD DISABLED
When Preset Method is disabled, the target rate on the Main Work screen
can be adjusted by pressing the Material Increment/Decrement buttons.
The target rate increases or decreases based on the Inc/Dec % value set at
the Material Configuration screen.
NOTE:
Rate changes can only occur
on actively viewed control
channels.
Figure 39
Material Configuration Setup Screen-Preset Method Disabled
TARGET RATE
The desired rate of application displays in KS (thousand) seeds per acre or
(KS/Ha).
MAXIMUM RATE
The maximum application rate in KS (thousand) seeds per acre or (KS/Ha)
that the control allows. Target Rate cannot be incremented to a value
greater than this established maxim rate.
MINIMUM RATE
The minimum application rate in KS (thousand) seeds per acre or (KS/Ha)
that the control allows. Target Rate cannot be decremented to a value lower
than this established minimum rate.
INCREASE/DECREASE %
Establishes the percentage of change of the entered target rate that is
applied each time the Material Increment/Decrement button is pressed on
the Main Work Screen.
IMPORTANT: The Maximum or Minimum Rates may not be reached if
the % increase or decrease, based off the Target Rate,
exceeds the maximum or minimum rate limits set.