beautypg.com

Figure 1, B) c) – HP 220 User Manual

Page 183

background image

9Ć5

Product History and Service Notes

C3187Ć90000

A) How/Where to Measure the Distance

a) Power off the unit.

b) Ensure that the pinchĆarm lever is in the UP position.

c) Open the window and remove the bail.

d) Slide the carriage (with both cartridges loaded) to the right until the right black and

yellow strip ofthe carriage is above the right sideplate (see figure 1.c).

e) Carefully try to insert, one at a time, the following gauges below the left cartridge,

(figure 1.b):

* 0.6 mm (0.025 in) - gauge should enter without any effort

* 0.7 mm (0.027 in) - gauge rubs slightly

* 0.8 mm (0.031 in) - gauge may enter but the carriage is lifted when you insert the

gauge.

Ifthe results are as described above, the distance is within specifications

b

Figure 1

90

d

Right Side Cover

Cartridge

Front View

Cartridge
Chute

a

b

c

Drive Roller

Surface

a)

Insert the gauges centered

below the left (fixed) cartridge.

Gauge

Carriage

side-view

90

d

Drive Roller

side-view

b)

c)

Ref.

Description

specs (mm)

a

ООООООООО

ООООООООО

nozzle platen to roller

0.9 to 1.3

ОООООООО

ОООООООО

glue bed to platen

0.2

c

ОООООООО

ОООООООО

glue bed to roller

0.7 to 1.1

This manual is related to the following products: