When tocalibrate the plotter, Service mode, Dnues:nn fesw:ge erde – HP 220 User Manual
Page 140

Align
Cartridges
7Ć2 Calibrations
C3187Ć90000
When toCalibrate the Plotter
Indications or Repairs Performed
Calibration Required
Jagged lines on plots
Cartridge Alignment
Cartridges are reseated or replaced
Cartridge Alignment
Drive roller is removed or replaced
Accuracy Calibration
Media (X-axis) motor is replaced
Accuracy Calibration
Configuration-plot X-mark distance is not
500mm (
"
1mm)
Accuracy Calibration
Carriage or carriage LED is removed or replaced
Cartridge Alignment
and Setup-Sheet Calibration
Edge-detect failures occur
Cartridge Alignment
Bail failures occur during media loading
Bail Calibration
Bail sensor is removed or replaced
Bail Calibration
Bail-lift mechanism is removed or replaced
Bail Calibration
Media sensor is removed or replaced
Media-Sensor Calibration
Leading and trailing margins of a plot are greater
than 17 mm (0.67 in)
Media-Sensor Calibration
Problems occur scanning a setup sheet.
Setup-Sheet Calibration
EEROM is cleared or main PCA is replaced
(In this order:)
1. Bail Calibration
2. Media-Sensor Calibration
3. Cartridge Alignment
4. Accuracy Calibration
5. Setup-Sheet Calibration
Service Mode
DnUeS:nN FeSW:Ge ERde
, Switch the plotter off.
. While holding the
Align Cartridges
key down,
switch the plotter on.
A Once the
Busy
LED lights up, release the