Mediaćsensor calibration – HP 220 User Manual
Page 147
![background image](/manuals/93490/147/background.png)
ALT
Media-Sensor
Calibration
7Ć9
Calibrations
C3187Ć90000
MediaĆSensor Calibration
The mediaĆsensor calibration measures the position of the mediaĆsensor levers with respect
to the drive roller. A value is stored in the EEROM when the procedure is completed.
Perform the mediaĆsensor calibration whenever:
D The EEROM is cleared
D The main PCA is replaced
D The media sensor is removed or replaced
D The leading and trailing margins of a plot are greater than 17 mm (0.67 in).
To calibrate the media sensor, perform the following procedure:
, Enter service mode D page7Ć2.
. Hold down the
ALT
key and press
Media Calibration
.
Any loaded media is ejected by the plotter.
A When the
Load Media
LED begins to flash, load a sheet of media in landscape orientation.
Th
adi g z
a
g
ha
a b a
h h
a gi
a
a
d
a i
. O
h h
i
ad d, i i j
d agai .
4 When the
Load Media
LED begins to flash again, load the same sheet in portrait
orientation.