1 Remove the electronicsĆenclosure

cover D page 6Ć5.

2 Remove the window D page 6Ć15.
3 Remove the center cover D page 6Ć16.
4 Remove the left endcover D page 6Ć18.
5 Lift the left front trim clear of the

plotter.

6 Remove the right endcover D page 6Ć19.
7 Remove the frontĆpanel

assembly D page 6Ć32.

8 Remove the carriage motor D page 6Ć35.
9 Remove the media motor D page 6Ć37.

10 Remove the encoder strip D page 6Ć39.
11 Remove the bail D page 6Ć56.
12 Remove the service station D page 6Ć57.
13 Remove the overdrive

roller D page 6Ć60.

In the following step, take care

not to damage the bail sensor.

C A U T I O N

14 Remove the three screws that attach the

mediaĆmotor mount to the right sideplate.
0einst2lling: Press down on the media

mount as you replace the three screws.

This is to ensure correct spacing between

the drive roller and the cartridge nozzles.

(Details D chapter 9.)

Press down here as

you tighten screws

MediaĆmotor mount

Torx-20

15 Unclip the cables from the holding clip

underneath the mediaĆmotor mount.

16 Lift the mount clear of the plotter.
17 Remove the screw that attaches the

media director to the chassis assembly

and remove the media director.

Media director

Torx-15

18 Pull the pinchĆarm lever forward to raise

the pinchĆarm assembly.

Pinch-arm lever

6Ć69

Removal and Replacement