C. vent components diagrams (continued) – Heat & Glo Fireplace XLR-PLUS-PB-AU User Manual
Page 73
73
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. o • 1/13
SLP-TRAP
Horizontal Termination Cap
15-1/8 in.
(384 mm)
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be
used on a wall 4 in. (102 mm) to 7-1/4 in. (184 mm) thick. If wall thickness is less than 4 in. (102 mm)
the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a
DVP-HSM-B will be required.
Heat
Shield
Term Cap
Minimum
Effective Length
Maximum
Effective Length
Trap
133 mm
235 mm
8 in.
(203 mm)
12 in.
(305 mm)
Max
Effective
Length
5-1/4 in.
9-1/4 in.
13 in.
(330 mm)
15 in.
(381 mm)
8-1/8 in
(206 mm)
10-7/8 in.
(276 mm)
10-1/2 in.
(267 mm)
3°
87°
Effective Length
5-3/4 in to 8-3/8 in.
(146 mm to 213 mm)
5-1/2 in.
(140 mm)
8-3/8 in.
(213 mm)
SLP-HRC-SS
SLP-HRC-ZC-SS
HORIZONTAL TERMINATION CAP
C. Vent Components Diagrams (continued)
Figure 17.7 SLP Series Vent Components