C. vent components diagrams (continued) – Heat & Glo Fireplace XLR-PLUS-PB-AU User Manual

Page 73

background image

73

Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. o • 1/13

SLP-TRAP

Horizontal Termination Cap

15-1/8 in.

(384 mm)

Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be

used on a wall 4 in. (102 mm) to 7-1/4 in. (184 mm) thick. If wall thickness is less than 4 in. (102 mm)

the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a

DVP-HSM-B will be required.

Heat

Shield

Term Cap

Minimum

Effective Length

Maximum

Effective Length

Trap

133 mm

235 mm

8 in.

(203 mm)

12 in.

(305 mm)

Max

Effective

Length

5-1/4 in.

9-1/4 in.

13 in.

(330 mm)

15 in.

(381 mm)

8-1/8 in

(206 mm)

10-7/8 in.

(276 mm)

10-1/2 in.

(267 mm)

87°

Effective Length

5-3/4 in to 8-3/8 in.

(146 mm to 213 mm)

5-1/2 in.

(140 mm)

8-3/8 in.

(213 mm)

SLP-HRC-SS

SLP-HRC-ZC-SS

HORIZONTAL TERMINATION CAP

C. Vent Components Diagrams (continued)

Figure 17.7 SLP Series Vent Components