Symptom

Possible Cause

Corrective Action

4. Pilot lights but contin-

ues to spark, and main

burner will not ignite.

(If the pilot continues

to spark after the

pilot flame has been lit,

flame rectification has

not occurred.)

a. A shorted or loose connection in flame

sensing rod.

Verify all connections to wiring diagram in manual. Verify

connections underneath pilot assembly are tight. Verify con-

nections are not grounding out to metal chassis, pilot burn-

er, pilot enclosure or screen if present, or any other metal

object.

b. Poor flame rectification or contaminated

flame sensing rod.

With fixed glass assembly in place, verify that flame is en-

gulfing flame sensing rod on left side of pilot hood. Flame

sensing rod should glow shortly after ignition. Verify cor-

rect pilot orifice is installed and gas inlet is set to pressure

specifications. Polish flame sensing rod with fine steel wool

to remove any contaminants that may have accumulated on

flame sensing rod.

c. Module is not grounded.

Verify module is securely grounded to metal chassis of ap-

pliance. Verify that wire harness is firmly connected to the

module.

d. Damaged pilot assembly or contami-

nated flame sensing rod.

Verify that ceramic insulator around the flame sensing rod

is not cracked, damaged, or loose. Verify connection from

flame sensing rod to white sensor wire. Polish flame sens-

ing rod with fine steel wool to remove any contaminants

that may have accumulated on flame sensing rod. Verify

continuity with a multimeter with ohms set at lowest range.

Replace pilot if any damage is detected.

e. Module.

Turn ON/OFF rocker switch or wall switch to OFF position.

Remove ignitor wire “I” from module. Place ON/OFF rocker

switch or wall switch in ON position. If there is no spark at “I”

terminal module must be replaced. If there is a spark at “I”

terminal, module is fine.

5. Carbon Deposition

a. Log Placement

Verify placement and assure flame is not excessively

impinging on log.

b. Shutter Setting

Check to assure correct shutter setting for your model and

gas type.

c. Gas Type

Assure correct fuel matches unit gas model and compo-

nents.