D. Junction Cord Information
The junction cord is installed at the factory. Refer to Figure
12.2 and 12.3. for more information.
E. Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105 °C (221 °F) rated wire. Wire must have high tem-
perature insulation.
Note: There is an alternative access to the junction cord.
This can be accessed by removing the valve assembly. See
Figures 11.2 and 11.3.
Figure 12.2. Junction Cord Information
BLUE
BROWN
GREEN/
YELLOW
Figure 12.3 Blower Circuit-
F. Blower
These heaters have a factory-installed fan and electrical
junction cord. These components are located behind the
lower door.
Use of the fan requires that the Junction cord (factory in-
stalled) be connected to 220/240 VAC service before per-
manently enclosing the heater. The service cord is found
on the right exterior side of the unit. See Figure 12.3 for
wire connection detail.
240V BLOWER
JUNCTION CORD
AUX 300 CE
GROUND TERMINAL TO
FIREPLACE CHASSIS