beautypg.com

Heat & Glo Fireplace XLR-PLUS-PB-AU User Manual

Page 59

background image

59

Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. o • 1/13

Figure 13.14. Dimensions of Tonic Decorative Front.

A

B

D

C

E F

TONIC FRONT

Figure 13.15 Glass and Heat Shield - Martini and Tonic

Figure 13.16 Martini Front Gap

Figure 13.17Tonic Front Gap

Glass Lip Heat Shield seats in glass frame.

Gap below Martini front

must not be covered - it

is for cool air flow when

the fan is running.

Gap between Tonic front and Tonic glass lip. This

gap is for cool air flow when fan is running.

LOWER GLASS HEAT SHIELD

(MARTINI & TONIC FRONTS)

UPPER GLASS HEAT SHIELD

(TONIC ONLY)

Retain top upper glass heat shield with tinnerman clip on

each side of glass frame.

This appliance requires field-installation of heat shield(s) on

the firebox glass frame. These shields function to manage

convective heat transfer during blower operation. These

shields are critical to the performance and reliability of the

appliance because they prevent overheating of gas control

components.

For installation finished with the Martini decorative front, a

single lower glass heat shield is installed in the bottom of the

glass frame. This shield will be installed prior to installing the

decorative surround and glass. See Figure 13.15. It is also

critical that the required air space is maintained between the

underside of the Martini surround and the adjacent finishing

materials. See Figure 13.16.

For installations finished with the Tonic decorative front, both

an upper and lower glass heat shields are installed in the top

and bottom of the firebox glass frame. These will be installed

prior to installing the framed mesh and the Tonic surround.

See Figures 13.15 and 13.16.

WARNING! Risk of Valve / Control Damage! This appliance

requires field-installation of heat shields onto the firebox glass

frame. Do not operate this appliance without the specified heat

sheild(s).

A

Top of decorative front to bottom of

appliance.

TN-SLR-**

26-3/8 in.

670 mm

TN-XLR-**

27-1/8 in.

689 mm

B

Bottom of decorative front to bottom of

appliance.

6-7/8 in.

175 mm

C

Inside dimension of decorative front

(width).

39 in.

991 mm

D

Outside dimension of decorative front

(width).

44-1/2 in. 1130 mm

E

Inside dimension decorative front

(height).

TN-SLR-**

13 in.

330 mm

TN-XLR-**

13-3/4 in.

349 mm

F

Outside dimension of decorative front

(height).

TN-SLR-**

19-1/2 in.

495 mm

TN-XLR-**

20-1/4 in.

514 mm

This manual is related to the following products: