Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. o • 1/13

Figure 7.5 Vertical Vent Maximum

Note: If installing a vertical vent/termination off the top of the

appliance, the optional exhaust restrictor may be needed.

V

1

V

1

Max= 13.4 m ( 44 ft.)

Top Vent - Vertical Termination

No Elbows

Note: Use SLP Series

components only.

Exhaust Restrictor Instructions
1. Locate the inner firebox exhaust restrictor. Figure 7.6.

Exhaust restrictors are recommended for these vertically

terminated products which have excessive draft. Exhaust

restrictors will compensate for high draft. and restore vi-

sual flame height. If the vent configuration has a total ver-

tical of 6-1/2 ft. - 44 ft. (2 m - 13.4 m), an exhaust restrictor

may be needed. The exhaust restrictor is located in the

appliance manual bag.

3. Replace existing restrictor with small cut-out restrictor

in manual bag for installations with more than 6-1/2 ft.

(2 m) of vertical piping. See Figure 7.7.

Figure 7.6 Standard Restrictor

Figure 7.7 Restrictor with Small Cut-Out

2. Remove restrictor for XLR-LOGS kit.