B. mantel and wall projections – Heat & Glo Fireplace XLR-PLUS-PB-AU User Manual
Page 56
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. o • 1/13
56
B. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specified. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.)
Failure to comply could cause fire.
Note: For non-combustible fireplace finish material (marble,
stone, etc) specifications refer to Section 13.C.
Figure 13.5 Clearances To Mantels Above Appliance.
Mantels (Combustible/Non-Combustible)
Figure 13.6 Non-Combustible Mantel Leg or Wall
Projections
(Acceptable on both sides of opening)
UNLIMITED
TOP VIEW
3-1/8 in.
(80 mm)
MINIMUM
FRAMING
1-1/8 in. (30 mm)
3/8 in (10 mm) BUILDING MATERIAL
1-1/2 in. (37 mm)
Front Side Finishing Detail
Figure 13.7 Front Side Finishing Detail
14-1/8 in
(360 mm)
MIN.
12 in. (300 mm)
MAX.
3/8 in. (10 mm)
Thick Wall
Sheathing
MEASUREMENT
FROM TOP OF
FIREPLACE
OPENING
Note: For non-combustible fireplace finish material (marble,
stone, etc) specifications refer to Section 13.C.
Mantel Leg (Combustible/Non-Combustible)