Configuring rip for the interface – Enterasys Networks Network Card User Manual
Page 74

62
RiverMaster Administrator’s Guide
Routing
Chapter 3
Configuring an ANG-3000/7000
Configuring RIP for the Interface
To configure RIP on an interface, perform the following steps:
1
Add RIP as described in the previous section or select RIP from the
Routing Protocols list and click Properties.
The RIP Interface Configuration window appears as shown in
Figure 36.
Figure 36 Routing Interfaces Configuration - RIP
2
Choose the version of RIP to use on this interface.
RIP Version 1 uses IP broadcast packets for periodic announcements
of reachable subnets. RIP Version 2 is an enhanced version of RIP that
uses IP multicast packets for announcements.
3
In the RIP Authentication fields, choose the algorithm used by routers
on your network.
If the routers on your network do not require passwords to accept
RIP updates, set the algorithm to None and skip to Step 7.
These values are
used to authenticate
RIP updates from
routers on the network