5 click add, 6 do one of the following – Enterasys Networks Network Card User Manual
Page 253

RiverMaster Administrator’s Guide
241
Appendix B
Configuring Routing Interfaces
ANG-3000/7000 Preconfiguration Stored on a Floppy Disk
3
In the Gateway address fields, type the IP address of a gateway on
this subnet.
For External interfaces, enter the IP address of the router that
provides access to the Internet.
4
In the Reachable Subnet fields, type a starting IP address and subnet
mask to define a subnet.
Packets received by the ANG are statically routed to the gateway you
specified. To forward all packets to the gateway when there is no
other reachable “next hop” address for a packet, enter an address of
0.0.0.0
and a subnet mask of 0.0.0.0.
CAUTION
Configuring a default static route (0.0.0.0/0.0.0.0) on the Trusted interface
of the ANG disables Intelligent Client Routing. Refer to “Intelligent
Client Routing” in Chapter 3 for more information.
5
Click Add.
The static route you set appears in the Internal Static Routes display.
6
Do one of the following:
–
Click Apply to create the static route, click Cancel to close the
window, and click Next to continue configuration. The Remote
Connections Configuration window appears.
–
Click Reset to return the interface’s protocol properties to their
default settings.
–
Click Cancel to close the window without saving your changes.