ProSoft Technology ILX34-AENWG User Manual
Page 144
Ladder Logic
ILX34-AENWG ♦ Point I/O Platform
User Manual
Wireless POINT I/O Adapter
Page 144 of 177
ProSoft Technology, Inc.
August 16, 2013
Error Bit
Description
6
A configuration was selected that requires the scalar and none was programmed OR
Multiple scalars were selected.
5
The preset is out of range (Rollover).
4
A rollover of zero was programmed through PWM was not selected OR
A rollover was programmed and PWM was selected OR
Rollover is out of range (>0x01000000).
3
A configuration requiring a time base was selected and no gate interval was set OR
Gate interval is out of range (>200) OR
Product of time base and gate interval is greater than 3 seconds.
2
A time base was entered that is not a multiple of 10 OR
Time base is out of range (>3000, or 3 seconds).
1
ZF/BF/AF were selected and no filter was programmed OR
Multiple filters were selected.
0
A reserved configuration/mode was programmed.
1734-IJ, 1734-IK
1734 POINT I/O Catalog Number
RSLogix5000 Module Description
1734-IJ
1 Channel 5V dc Encoder / Counter
1734-IK
1 Channel 15…24V dc Encoder / Counter
Output Data
Data Type
Default Value
Valid Data Values
Counter Control
SINT
0
Counter Reset
BIT 0
0
0=Count Unchanged
1=Count Cleared
Counter Preset
BIT 1
0
0=Count Unchanged
1=Count Set to Preset
Value Reset
(Stored / Accumulated Count)
BIT 2
0
0=Count Unchanged
1=Count Cleared
1734-SSI
1734 POINT I/O Catalog Number
RSLogix5000 Module Description
1734-SSI
1 Channel Synchronous Serial Interface
Configuration Data
Data Type
Default Value
Valid Data Values
Run
SINT
1
0=Module Not Running
1=Module Is Running
Gray Binary
SINT
1
0=Binary Code
1=Gray Code
Word Length
SINT
13
2…31