PECIFICATIONS
Power Input
Humidity
Max Loop Resistance
Loop Delay Time
FUSES
Mains Supply Fuse
Aux Fuse
Keypad Fuse
Battery Fuse
Low Voltage Output
Maximum Output Current
GT490X
Battery Sizes
Construction
Complies with
Conforms with
Number of Zones
(Standard)
Expansion Type
Number of Keypads
Zone Descriptors
Max No of Users
230V a/c ±10% @ 50Hz
70% non condensing
2K (not with E.O.L.)
400mS
20mm 125mA Anti-Surge
Resettable
Resettable
Resettable
13.65V dc Regulated +/-0.3V
0.8A plus 0.123mA for battery charge.
12V 1.2A, 2A, 3A, 7A
Metal
EN50131-1 PD6662
CE tested
EMC Directive 89/336/EEC
& LVD Directive 73/23/EEC
8 (2 Wire), 9 (EOL), 8+8 (EOL)
1 Radio Expanders may be fitted
4 Normal
16 Characters (last 3 omitted with tamper)
15 + Engineer