PECIFICATIONS

Power Input
Humidity

Max Loop Resistance
Loop Delay Time

FUSES
Mains Supply Fuse
Aux Fuse
Keypad Fuse
Battery Fuse

Low Voltage Output

Maximum Output Current
GT490X

Battery Sizes

Construction

Complies with

Conforms with

Number of Zones
(Standard)

Expansion Type

Number of Keypads

Zone Descriptors

Max No of Users

230V a/c ±10% @ 50Hz
70% non condensing

2K (not with E.O.L.)
400mS

20mm 125mA Anti-Surge
Resettable
Resettable
Resettable

13.65V dc Regulated +/-0.3V

0.8A plus 0.123mA for battery charge.

12V 1.2A, 2A, 3A, 7A

Metal

EN50131-1 PD6662

CE tested
EMC Directive 89/336/EEC
& LVD Directive 73/23/EEC

8 (2 Wire), 9 (EOL), 8+8 (EOL)

1 Radio Expanders may be fitted

4 Normal

16 Characters (last 3 omitted with tamper)

15 + Engineer