GT490X Engineer’s Reference Guide

7

PD6662:2010 U

PDATE

-

NEW FEATURES

EN50131-1 2006 and BS8243

PD 6662, the document describing how the European standards for Intrusion and
Hold-up Alarm systems (I&HAS) should be applied in the UK, has been completely
revised. The revision takes into account the publication of a number of new, revised or
amended European standards. It also adds some new standards and documents
published by British Standards that add or vary requirements for alarm confirmation,
commissioning and maintenance and false alarm management.

PD 6662: 2010 will replace the 2004 version when it is published but for a two year
period (ending May 31st 2012) systems may be installed under either the 2004 or 2010
version of PD 6662.

The most significant changes are listed below.

Engineer Access.
Can now be turned off if the customer has agreed, (in writing). When entering the
engineer menu, the panel will generate an audible sound for approximately 8 seconds
to indicate that the engineer is on site, (grades 1, 2, and 3). For grades 2/3 the ATS
must also send an engineer on site signal.

Confirmed PA
Confirmed PA has been added to the Control Panel menu. (Programming Panic /
Panic). Please note that Confirmed PA can only be produced by activating two zones
programmed as panic or a keypad panic and a Panic zone.

If Mod + FF is used, the Alarm B channel will be transmitted for PA/Intruder
confirmation.
If Mod + PID is used the confirmed PA will transmit E129.
If Mod + SIA is used the confirmed PA will transmit HV.
Note: This would normally be used on systems that have lost police response for
Panic.