RISCO Group Gardtec 490X User Manual
Page 33

Page
32
GT490X Engineer’s Reference Guide
7)
Use the No key to scroll through the
Setting Modes.
Options available for Setting Modes are.
Set By Time
The system will Set after the Time shown in the
Exit Time.
Set By ET
The system will set when the Exit Terminator Button
outside the premises is pushed (this option will require
a Zone to be programmed as Exit Terminator).
Set By E/E
Once the user has started to Set the system the Exit Tones
will continue until the Final Exit Door is opened then closed.
This option will require a Door Contact.
Set By Time+E/E
Once the user has started to Set the system the system will
Set on either the Time expiring or the door opening and
closing. This option may require a Door Contact.
8)
When the Setting Mode you Require is displayed
press Yes. The display will show:-
9)
Press No. The display will show:-
10)
Press Yes. The display will show:-
11)
Press No twice. The display will show:-
12)
Enter the time you require as the Exit Time
(in seconds) followed by Yes.
The display will show for example:-
Program Setting
for FULL set ?
Program Setting
for PART 1 set ?
P1-Exit time =30s
=Set by TIME
P1-Exit time >_ _s
=Set by TIME
P1-Exit time =20s
>Set by TIME
PR5851 Rev12 490X Eng Ref Guide.qxd 10/05/2012 11:32 Page 32