Page, Wiring diagrams - gt490x pcb, 6gt490x engineer’s reference guide – RISCO Group Gardtec 490X User Manual
Page 7: Connections available are model dependant

Wiring Diagrams - GT490X PCB
Page
6
GT490X Engineer’s Reference Guide
- + -
STROBE BELL
BELL
SAB PGM1 SPR+ SPR + - + - + - +
- + - + - + - + - + -
+ -
AON
AIN
AOUT
HOLD
TMPR
AUX 12V
TZ
AZ1
AZ2
AZ3
AZ4
AZ5
AZ6
AZ7
AZ8
RS485 REMOTE KEYPAD PGM2
RED BLK YEL
GRN D2 D1 0V 12V
BA
TT
AC
- +
PAT
C
H
LEAD
CONNECTION
KEYPAD
CONNECTIONS
RS485 (RADIO EXPA
NDER)
CONNECTIONS
EXTERNAL
SOUNDER
/ STROBE MODULE
INTERNAL
SPEAKERS
MIN 16 OHM
REMOTE
KEYP
AD(S)
MA
Y
BE WIRED
IN ST
AR OR
DAISYCHAIN
FORMA
T
D2/B D1/A 0V 12V
D2/B D1/A
0V 12V
PSTN OUT LINE IN
C3 B2 A5 B2 A5
TELEPHONE CONNECTIONS
LINE
IN
3
2
5
OTHER
SOCKETS
ON PREMISES
GT
AG
PROXIMITY
READER(S)
Note: 680 Ohm
resistor should
be fitted to ONE
of the RKPs. If
RKPs are wired
in daisy chain
this should be
the last RKP
in
the line,
EXT
MODEM
IN
0V
12V
OUT
T
AMPER
JUMPER
J1
Strobe - Trigger
Bell / Strobe + Hold-Off
Bell - Trigger
Bell Hold-Off - Supply
- Tamper Return
Default Engineer Code
1234
.
Default User
5678
.
T
o
Default Panel
Power Up.
Whilst version No.
is displayed enter
4 6
Y
e
s No.
This will not Default
the Engineer Code
if it has been locked.
Connections available are
model dependant
680 Ohm
Case
T
a
mper / Bypass Jumper
PR5851 Rev12 490X Eng Ref Guide.qxd 10/05/2012 11:32 Page 6