GT490X Engineer’s Reference Guide
4)
Press No until the required setting is displayed
then press Yes. The display will show:-
5)
Press No until the required setting is displayed
then press Yes. The display will show:-
Please note that Confirmed PA can only be produced by activating two zones
programmed as panic or a keypad panic and a Panic zone.
If Mod + FF tis used the Alarm B channel will be transmitted for PA/Intruder
confirmation.
If Mod + PID is used the confirmed PA will transmit E129.
If Mod + SIA is used the confirmed PA will transmit HV.
6)
Press Yes. The display will show:-
Note: Duress is defaulted to Off and cannot be changed.
7)
This concludes the programming for
Panic. Press 0 (zero) to return to:-
Or
Press 0 (zero) until the display shows:-
PA = Bells Only
> Non-Testable
Duress :Off
Program . . . . _ _ _
Panic / Duress
01 Jan 00: 00: 01
PA Confirm
=Off