RISCO Group Gardtec 490X User Manual
Page 26
![background image](https://www.manualsdir.com/files/858589/content/doc026.png)
Page
25
GT490X Engineer’s Reference Guide
Comprehensive instructions on how to setup and program the Radio Expansion
are given in the document Hybrid Wireless Set-Up & Programming Guide
supplied with the Radio Receiver.
33)
Press Yes. The display will show:-
34)
Press No. The display will show:-
35)
Press No. The display will show:-
36)
Press Yes. The display will show:-
Any 12Hr type zone(s) may be placed on Test. A Zone on Test will never trigger
an alarm or send a central station signal. If the Zone(s) fails the Test when the
system is Set the display will show Test Fail when the user Un-Sets the system.
After 20 successful Sets and Un-Sets the Zone(s) will be taken out of Test by the
system.
Zones on soak test.
Zones that are put on test must be indicated to the user. When setting the system the
user must acknowledge this by pressing No.
37)
If you do not wish to put a Zone(s) on Test press
Yes and jump to Step 43
Otherwise
38)
Press No. The display will show:-
39)
Enter the Zone number you wish to place on Test
followed by Yes.
The display will show for example:-
40)
To add more Zone(s) to the Test repeat from
Step 38.
Program Radio
Functions ?
Program Zone
Wiring ?
Program Zone
Attributes ?
Test None
Test 003
Enter Zone # _ _ _
then +YES or -NO
PR5851 Rev12 490X Eng Ref Guide.qxd 10/05/2012 11:32 Page 25