GT490X Engineer’s Reference Guide
6 4 W
IRE
C
ONTOUR
RKP W
IRING
I
NFORMATION
Note: All keypads on the same system MUST be of the same type. i.e. All four wire or
all six.
Note: All Keypads MUST be connected before powering up the Control
Panel.
CPX
Keypad Connection Details
REMOTE KEYP
AD
D2 D1 0V 12V
KEYP
AD
CONNECTIONS
REMOTE
KEYPAD(S)
MAY BE WIRED
IN STAR OR
DAISYCHAIN
FORMAT
D2/B D1/A
0V 12V
Note: 680 Ohm resistor should
be fitted to ONE of the RKPs.
If RKPs are wired in daisy chain
this should be the last RKP in
the line,
Remove 2K2
if using Keypad
Zones and use
resistor EOL.
GTAG
PROXIMITY
READER(S)
4 Wire Contour RKP
A1 & A2, if used, are connected
to the first reader (antenna).
If using an second reader, remove
the link and connect between A3 & A4.
680 Ohm
2K2
Note: Both detectors must be run on a single cable
from the Keypad to the first detector
then the second. The 2K2 resistor must be in the
last/final detector.
Zone 12V 0V
D1
D2
3K3
2K2
5K6
Alarm N/C Tamper N/C
1st Detector
2nd Detector
+ Power -
Alarm N/C Tamper N/C
+ Power -
RKP
0V
D1
Zone 12V
D2
5K6
2K2
3K3
2nd Detector
Door Contact
Alarm N/C Tamper N/C
+ Power -
RKP
Alarm
Note: Keypad zones are
preset and cannot be changed.
E/E - 3K3 KP Zone 1
Part E/E - 5K6 KP Zone 2
EOL - 2K2
Keypad Zone Wiring Details
GT490X Keypad Connection Details
PR5851 Rev12 490X Eng Ref Guide.qxd 10/05/2012 11:33 Page 101